2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 1748
* Water intrusion in the B52 HO2S harness connector
* Low or high fuel system pressure-Refer to Fuel System Diagnosis (w/o FPCM) (See: Powertrain Management/Computers and Control
Systems/Testing and Inspection/Component Tests and General Diagnostics)Fuel System Diagnosis (FPCM) (See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Component Tests and General Diagnostics)
* Fuel that is contaminated-Refer to Alcohol/Contaminants-in-Fuel Diagnosis (Without Special Tool) (See: Powertrain
Management/Computers and Control Systems/Testing and Inspection/Component Tests and General
Diagnostics/Alcohol/Contaminants-in-Fuel Diagnosis (Without Special Tool))Alcohol/Contaminants-in-Fuel Diagnosis (Special Tool) (
See: Powertrain Management/Fuel Delivery and Air Induction/Fuel/Testing and Inspection/Alcohol/Contaminants-in-Fuel Diagnosis
(Special Tool))
* Fuel saturation of the evaporative emission (EVAP) canister
* Exhaust leaks near the B52 HO2S
* Engine vacuum leaks
* Engine oil consumption-Refer to Oil Consumption Diagnosis (See: Engine, Cooling and Exhaust/Engine/Testing and
Inspection/Component Tests and General Diagnostics/Oil Consumption Diagnosis)
* Engine coolant consumption-Refer to Loss of Coolant (See: Engine, Cooling and Exhaust/Cooling System/Testing and
Inspection/Symptom Related Diagnostic Procedures/Loss of Coolant)
瀚慖f you find any of the above conditions, repair as necessary.
2. If all conditions test normal, test or replace the appropriate B52 HO2S.
Repair Instructions
Caution: Refer to Heated Oxygen Sensor Resistance Learn Reset Caution (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service Precautions/Heated Oxygen Sensor Resistance Learn Reset Caution).
Perform the Diagnostic Repair Verification (See: Verification Tests) after completing the diagnostic procedure.
* Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (1500 Series) (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 1 Sensor 1 (2500 Series) (See: Powertrain
Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)
* Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (1500 Series) (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 1 Sensor 2 (2500 Series) (See: Powertrain
Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)
* Heated Oxygen Sensor Replacement - Bank 2 Sensor 1 (1500 Series) (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 2 Sensor 1 (2500 Series) (See: Powertrain
Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)
* Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (1500 Series) (See: Powertrain Management/Computers and Control
Systems/Oxygen Sensor/Service and Repair)Heated Oxygen Sensor Replacement - Bank 2 Sensor 2 (2500 Series) (See: Powertrain
Management/Computers and Control Systems/Oxygen Sensor/Service and Repair)
* Control Module References (See: Testing and Inspection/Programming and Relearning) for ECM replacement, setup, and programming
P014A
DTC P0133, P013A-P013F, P014A, P014B, P0153, P1133, or P1153
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic System
Check - Vehicle) prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Strategy Based Diagnosis) for an
overview of the diagnostic approach.
* Diagnostic Procedure Instructions (See: Testing and Inspection/Initial Inspection and Diagnostic Overview/Diagnostic Procedure
Instructions) provides an overview of each diagnostic category.
DTC Descriptors
DTC P0133
- HO2S Slow Response Bank 1 Sensor 1
DTC P013A
- HO2S Slow Response Rich to Lean Bank 1 Sensor 2
DTC P013B
- HO2S Slow Response Lean to Rich Bank 1 Sensor 2
DTC P013C
- HO2S Slow Response Rich to Lean Bank 2 Sensor 2