Monday, November 11, 2019

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 301

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 301

Circuit/System Description

The liftgate module (LGM) receives an input from the liftglass ajar switch. The ajar switch is normally open when the liftglass is fully closed.

When the liftglass is opened, the ajar switch contact closes providing a path to ground. The driver information center (DIC) illuminates the Rear

Access Open message when the liftglass is open.

Conditions for Running the DTC

System voltage to the liftgate control module must be 9-16 volts.

Conditions for Setting the DTC

B396F 06

The LGM detects a short to ground or an open/high resistance in the liftglass ajar signal circuit.

B396F 0B

The LGM detects a short to voltage in the liftglass ajar signal circuit.

Action Taken When the DTC Sets

* When a short to ground condition is present, the Rear Access Open indicator will be continuously illuminated.

* When an open or short to voltage condition is present, the Rear Access Open indicator will not illuminate when the liftglass is open or ajar.

Conditions for Clearing the DTC

* The DTC will be current for as long as the fault is present.

* When the fault is no longer present, the DTC will be a history DTC.

* A history DTC will clear after 50 ignition cycles.

Reference Information

Schematic Reference

Release Systems Schematics (See: Body and Frame/Locks/Diagrams/Electrical Diagrams/Release Systems Schematics)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Door Ajar Indicator Description and Operation (See: Instrument Panel, Gauges and Warning Indicators/Door/Trunk Ajar

Indicator/Lamp/Description and Operation)

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Ignition ON, observe the scan tool Liftgate Ajar Switch parameters while opening and closing the liftglass. The parameter should change between

Active and Inactive.

Circuit/System Testing