Showing posts with label Conditions for Clearing. Show all posts
Showing posts with label Conditions for Clearing. Show all posts

Monday, November 11, 2019

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 369

2010 Cadillac Truck Escalade EXT AWD V8-6.2L Page 369

Conditions for Clearing

* The DTC will transition to history when the fault is no longer present.

* A history DTC will clear after 100 malfunction-free ignition cycles.

Diagnostic Aids

If the parking aid switch is continuously pressed for greater than 5 seconds the DTC will set.

Reference Information

Schematic Reference

Object Detection Schematics (See: Accessories and Optional Equipment/Collision Avoidance and Parking Assist Systems/Diagrams/Electrical

Diagrams)

Connector End View Reference

Component Connector End Views (See: Diagrams/Connector Views)

Description and Operation

Object Detection Description and Operation (UFT) (See: Accessories and Optional Equipment/Collision Avoidance and Parking Assist

Systems/Description and Operation/Object Detection Description and Operation (UFT))Object Detection Description and Operation (UVC) (See:

Accessories and Optional Equipment/Collision Avoidance and Parking Assist Systems/Description and Operation/Object Detection Description and

Operation (UVC))Object Detection Description and Operation (UD7) (See: Accessories and Optional Equipment/Collision Avoidance and

Parking Assist Systems/Description and Operation/Object Detection Description and Operation (UD7))

Electrical Information Reference

* Circuit Testing (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Circuit

Testing/Circuit Testing)

* Connector Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic

Procedures/Connector Repairs/Connector Repairs)

* Testing for Intermittent Conditions and Poor Connections (See: Testing and Inspection/Component Tests and General Diagnostics/General

Electrical Diagnostic Procedures/Circuit Testing/Testing for Intermittent Conditions and Poor Connections)

* Wiring Repairs (See: Testing and Inspection/Component Tests and General Diagnostics/General Electrical Diagnostic Procedures/Wiring

Repairs/Wiring Repairs)

Scan Tool Reference

Control Module References (See: Testing and Inspection/Programming and Relearning) for scan tool information

Circuit/System Verification

Ignition ON, observe the scan tool Park Assist Switch parameter while cycling the parking assist disable switch. The parameter should change

between Active and Inactive.

Circuit/System Testing

1. Ignition OFF, disconnect the harness connector at the I/P multifunction switch.

2. Test for less than 1.0 Ohms between the appropriate ground circuit listed below and ground:

* RPO X88/Z88 ground circuit terminal 3

* RPO Z75 ground circuit terminal 5

瀚慖f greater than the specified range, test the ground circuit for an open/high resistance.

3. Ignition ON, verify that the scan tool Park Assist Switch parameter is Inactive.

瀚慖f not the specified value, test the signal circuit terminal 2 for a short to ground. If the circuit tests normal, replace the object alarm

module.

4. Ignition OFF, connect a 3A fused jumper wire between signal circuit terminal 2 and ground.

5. Ignition ON, verify that the scan tool Park Assist Switch parameter is Active.

瀚慖f not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the

object alarm module.

6. If all circuits test normal, test or replace the I/P multifunction switch.